nctcog logo
 
environment & development label
 
  Back to Station Map          Back to Main Monitoring Page          Export Data

Station Info: WRC-300-15

 
Station ID Year Jurisdiction Watershed Location Description     Latitude         Longitude    
WRC-300-15 2015 Dallas City of Dallas-White Rock Creek 5100 C. F. Hawn Frwy at White Rock Creek 32.745551 -96.73078

Sampled Events

1st Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
1/31/2015 2/2/2015 . WRC-300-15 0.52 225
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
11:30:00 PM 11:00:00 AM 7:17:00 PM 8:40:00 PM 5 4.593 2.683 4 55.22 54.32
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
268 64 1.97 5 1.02 0.05 0.06 <0.061 0.002 2 0.004 0.036 <0.004 0.01 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
<1.4 8.18 5 0 377

2nd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
4/5/2015 4/5/2015 . WRC-300-15 0.92 689
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
9:00:00 AM 4:00:00 PM 2:57:00 AM 4:20:00 AM 5 5.24 2.83 4 54 60.08
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
342 37 3.73 11 6.27 0.06 0.09 <0.06 <0.002 2 0.004 0.01 <0.004 0.026 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
<1.4 8.94 200 0 556

3rd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
8/20/2015 8/20/2015 . WRC-300-15 0.45 1248
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
1:00:00 AM 9:00:00 AM 12:00:00 AM 1:41:00 AM 5 4.3 2.7 4 74.12 72.68
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
288 99 2.73 4 2.99 0.06 0.13 <0.061 0.004 4 <0.003 <0.001 <0.004 0.011 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
<1.4 7.5 16 0 503

4th Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
10/22/2015 10/24/2015 . WRC-300-15 5.16 1032
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
9:00:00 PM 1:00:00 PM 7:13:00 PM 8:46:00 PM 5 5.72 11.15 4 68.18 68.72
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
356 43 15.9 14 2.59 0.03 0.04 <0.06 0.002 2 <0.003 0.002 <0.004 0.011 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
<1.4 7.82 <1 0 553

Station Averages

Station TDS TSS BOD COD Nitrogen Phosphorus
(Dissolved)
Phosphorus
(Total)
Carbaryl Arsenic Chromium Copper Lead Zinc Diazinon Cadmium Oil &
Grease
E.
Coli
Coliform
(Total)
pH
Lab
pH
Field
Specific Conductivity
WRC-100-15 381 32.8 8.7 11 3.195 0.06 0.09 0.0311 0.002 0.04 0.0091 0.002 0.014 1.18 47 0 7.66 539.5
WRC-200-15 333 74 12.2 22 3.063 0.065 0.12 0.0309 0.002 0.02 0.008 0.004 0.0208 1.2 124 0 7.88 503.25
WRC-300-15 313.5 60.8 6.1 8.5 3.218 0.05 0.08 0.0303 0.002 0.003 0.0121 0.002 0.0145 0.7 9 0 7.87 497.25

Key:
< or > - Amount detected is above or below equipment detection limit A - Approximate end time of flow due to power failure A-01 - >400000
B-02 - BOD result calculated from COD analysis D-1 - Elevated reporting limit(s) due to dilution. This has no effect on the data. Sample result is considered valid. DET - Analyte Detected
DRY – Sample results reported on a dry weight basis E - End time of flow due to equipment removal from site IS - Insufficient Sediment within Sample
J - Detected but below the reporting limit N/A - Data not available at this time ND - Analyte not detected at or above the reporting limit
NR - Not Reported NST – No Sample Taken U - Undetected
W-05 - Highest possible dilutions were made by the laboratory Qual – Qualifiers Q-5 - Seed correction outside desired limits. This has no effect on the data. Sample result is considered valid.
Q11 - Insufficient sample for analysis of matrix spike. This has no effect on the data. Sample result is considered valid. RPD - Relative Percent Difference S-1 - Laboratory container pH was above desired amount. This has no effect on the data. Sample result is considered valid.
TNTC - Too numerous to count U – Undetected W-05 - Highest possible dilutions were made by the laboratory
     
BOD - Biochemical Oxygen Demand BRL - Below Reading Limit COD - Chemical Oxygen Demand
TDS - Total Dissolved Solids TSS - Total Suspended Solids by EPA 160.2 PC - Sample results suspect due to post-calibration results
**This data was only collected in the second permit term. ***This data is only being collected in the third permit term.  


Back to Station Map          Back to Main Monitoring Page          Export Data
 
 CONTACT US | SITE MAP | LEGAL | SYSTEM REQUIREMENTS
 North Central Texas Council of Governments | 616 Six Flags Drive P.O. Box 5888 Arlington, TX 76005-5888
 Main Operator: (817) 640-3300 | Fax: (817) 640-7806