Station ID Year Jurisdiction Watershed Location Description     Latitude         Longitude    
TX0702 2007 TXDOT Muddy Creek Muddy Creek at SH-78 32.9819694 -96.5860777

Sampled Events

1st Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
1/3/2007 11:05:00 PM 1/4/2007 5:00:00 AM An area of low pressure brought rain showers across the metroplex moving from the southwest to the northeast TX0701 0.84 0.25 112
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
1/3/2007 11:40:00 PM 1/4/2007 2:45:00 PM 1/3/2007 11:47:00 PM 1/4/2007 2:19:00 AM 7 2.26 0.5 4 All aliquots were successfully collected. An additional aliquot was collected at the end of the program due to programming modifications. The sample is considered valid.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
330 47.5 <3 U 15.9 2.43 0.0647 0.098 *** 0.002 J 0.003 J <0.008 U <0.004 U 0.021 J <0.037 U <0.001 U
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 7.83 6.67 100 14000 ***

2nd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
4/3/2007 6:10:00 PM 4/3/2007 7:50:00 PM A frontal boundary brought rain showers across the metroplex moving from northwest to southeast TX0701 0.12 0.07 87
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
4/3/2007 7:05:00 PM 4/3/2007 9:55:00 PM 4/3/2007 7:37:00 PM 4/3/2007 9:40:00 PM 6 0.6 0.4 3.5 The sampling equipment was removed at the conclusion of the sampling activities
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
495 72.5 22 900 21.5 <0.05 U <0.05 U *** <0.002 U 0.02 J 0.0251 J 0.043 J 0.0385 J <0.037 U 0.00113 J
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 7.75 8.33 <10 U 112 ***

3rd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
7/26/2007 6:30:00 PM 7/26/2007 8:40:00 PM Rain associated with afternoon thunderstorms occurred across the Eastern portions of Dallas County TX0701 0.28 0.26 311
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
7/26/2007 6:30:00 PM 7/26/2007 9:15:00 PM 7/26/2007 6:30:00 PM 7/26/2007 8:32:00 PM 6 1.3 0.7 3.5 The flow end time and date are a result of the sampling equipment being removed at the conclusion of the sampling activities
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
300 124 15 20.6 2 <0.05 U <0.05 U *** 0.015 J <0.008 J 0.0536 J <0.004 U 0.0632 J <0.037 U <0.001 U
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
3.77 J 7.53 8.14 20000 82000 ***

4th Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
10/15/2007 10:20:00 PM 10/16/2007 2:15:00 AM Wide spread showers and thunderstorms developed in advance of a cold front moving across the DFW Metroplex. TX0701 0.91 0.83 147
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
10/15/2007 11:05:00 PM 10/16/2007 2:00:00 AM 11:49:00 PM 1:52:00 AM 6 1.8 0.4 3.5 68 The flow end time and date are a result of the sampling equipment being removed at the conclusion of the sampling activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
228 145 11.3 75 <0.05 U <0.05 U 0.39 *** 0.014 J 0.01 J 0.02687 J 0.019 J 0.128 J <0.037 U 0.001 J
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
6.32 7.54 8.8 14000 526000 ***

Station Averages

Station TDS TSS BOD COD Nitrogen Phosphorus
(Dissolved)
Phosphorus
(Total)
Carbaryl Arsenic Chromium Copper Lead Zinc Diazinon Cadmium Oil &
Grease
E.
Coli
Coliform
(Total)
pH
Lab
pH
Field
Specific Conductivity
TX0701 167.3 215.8 7.6 41.6 1.93 0.0426 0.167 0.006 0.005 0.0318 0.011 0.0391 0.0185 0.0005 3.79 561 46245 7.47 6.65
TX0702 338.3 97.3 12.5 252.9 6.489 0.0349 0.135 0.008 0.009 0.0274 0.017 0.0627 0.0185 0.0008 2.87 612 16126 7.64 7.25

Key:
< or > - Amount detected is above or below equipment detection limit A - Approximate end time of flow due to power failure A-01 - >400000
B-02 - BOD result calculated from COD analysis D-1 - Elevated reporting limit(s) due to dilution. This has no effect on the data. Sample result is considered valid. DET - Analyte Detected
DRY – Sample results reported on a dry weight basis E - End time of flow due to equipment removal from site IS - Insufficient Sediment within Sample
J - Detected but below the reporting limit N/A - Data not available at this time ND - Analyte not detected at or above the reporting limit
NR - Not Reported NST – No Sample Taken U - Undetected
W-05 - Highest possible dilutions were made by the laboratory Qual – Qualifiers Q-5 - Seed correction outside desired limits. This has no effect on the data. Sample result is considered valid.
Q11 - Insufficient sample for analysis of matrix spike. This has no effect on the data. Sample result is considered valid. RPD - Relative Percent Difference S-1 - Laboratory container pH was above desired amount. This has no effect on the data. Sample result is considered valid.
TNTC - Too numerous to count U – Undetected W-05 - Highest possible dilutions were made by the laboratory
     
BOD - Biochemical Oxygen Demand BRL - Below Reading Limit COD - Chemical Oxygen Demand
TDS - Total Dissolved Solids TSS - Total Suspended Solids by EPA 160.2 PC - Sample results suspect due to post-calibration results
**This data was only collected in the second permit term. ***This data is only being collected in the third permit term.  


Back to Station Map          Back to Main Monitoring Page          Export Data
 
 CONTACT US | SITE MAP | LEGAL | SYSTEM REQUIREMENTS
 North Central Texas Council of Governments | 616 Six Flags Drive P.O. Box 5888 Arlington, TX 76005-5888
 Main Operator: (817) 640-3300 | Fax: (817) 640-7806