Station Info: PL1502

 
Station ID Year Jurisdiction Watershed Location Description     Latitude         Longitude    
PL1502 2015 Plano Pittman Creek Spring Creek Spring Creek and 16th Street 33.021317 -96.712406

Sampled Events

1st Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
1/1/2015 7:15:00 AM 1/1/2015 10:05:00 AM Large storms formed southwest of the Dallas Fort-Worth metroplex and moved across the region in a northeast direction bringing light to medium rainfall. PL1502 0.29 0.15 121
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
1/1/2015 7:35:00 AM 1/1/2015 10:40:00 AM 1/1/2015 7:49:00 AM 1/1/2015 9:52:00 AM 6 2 1.4 3.5 32 39.9 The flow end time and date are a result of the sampling equipment being removed at the conclusion of the sampling activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
306 95.5 1.91 <1 U 1.37 0.04 0.08 <0.06 U <0.002 U <0.003 U 0.024 <0.004 U 0.044 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 8.4 35000 100000 78

2nd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
4/5/2015 1:50:00 AM 4/5/2015 6:25:00 AM Large storms formed west of the Dallas Fort-Worth metroplex and moved across the region in an eastern direction bringing moderate rainfall. PL1502 0.15 0.07 333
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
4/5/2015 3:45:00 AM 4/5/2015 6:25:00 AM 4/5/2015 4:02:00 AM 4/5/2015 6:06:00 AM 6 1.4 1.1 3.5 51 59.9 The flow end time and date are a result of the sampling equipment being removed at the conclusion of the sampling activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
420 118.2 11.6 38 10 0.13 0.19 <0.06 U <0.002 U 0.003 J 0.018 <0.004 U 0.068 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 7.2 3700 11000 575

3rd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
7/8/2015 1:30:00 PM 7/8/2015 2:40:00 PM Storms formed west of the Dallas-Fort Worth metroplex and moved across the region in a northeast direction bringing heavy rainfall. PL1502 0.78 0.74 185
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
7/8/2015 1:40:00 PM 7/8/2015 4:00:00 PM 7/8/2015 1:54:00 PM 7/8/2015 3:57:00 PM 6 3.2 2.2 3.5 75 78.8 The flow end time and date are a result of the sampling equipment being removed at the conclusion of the sampling activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
184 286 15 7 4.54 0.06 0.11 <0.06 U <0.002 U 0.011 0.009 J <0.004 U 0.026 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
10.1 8.4 4000 9500 525

4th Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
10/22/2015 1:55:00 PM 10/22/2015 9:40:00 PM Large storms formed southwest of the Dallas Fort-Worth metroplex and moved across the region in a northeast direction bringing heavy rainfall. PL1502 1.14 0.48 792
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
10/22/2015 6:15:00 PM 10/22/2015 9:15:00 PM 10/22/2015 7:07:00 PM 10/22/2015 9:10:00 PM 6 3 2.1 3.5 68 71.6 Flow end time and date are a result of the sampling equipment being removed at the conclusion of activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
212 663 5.78 40 3.17 0.05 0.09 <0.06 U 0.004 J <0.003 U 0.004 J <0.004 U 0.016 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
2.45 J 7.9 1500 72000 288

Station Averages

Station TDS TSS BOD COD Nitrogen Phosphorus
(Dissolved)
Phosphorus
(Total)
Carbaryl Arsenic Chromium Copper Lead Zinc Diazinon Cadmium Oil &
Grease
E.
Coli
Coliform
(Total)
pH
Lab
pH
Field
Specific Conductivity
PL1501 96.5 75.4 6.8 13.4 4.688 0.065 0.108 0.0301 0.002 0.003 0.0143 0.002 0.0173 2.5 1916 13154 8.44 139.75
PL1502 280.5 290.7 8.6 21.4 4.77 0.07 0.118 0.03 0.002 0.004 0.0138 0.002 0.0385 3.49 5280 29452 7.68 366.5

Key:
< or > - Amount detected is above or below equipment detection limit A - Approximate end time of flow due to power failure A-01 - >400000
B-02 - BOD result calculated from COD analysis D-1 - Elevated reporting limit(s) due to dilution. This has no effect on the data. Sample result is considered valid. DET - Analyte Detected
DRY – Sample results reported on a dry weight basis E - End time of flow due to equipment removal from site IS - Insufficient Sediment within Sample
J - Detected but below the reporting limit N/A - Data not available at this time ND - Analyte not detected at or above the reporting limit
NR - Not Reported NST – No Sample Taken U - Undetected
W-05 - Highest possible dilutions were made by the laboratory Qual – Qualifiers Q-5 - Seed correction outside desired limits. This has no effect on the data. Sample result is considered valid.
Q11 - Insufficient sample for analysis of matrix spike. This has no effect on the data. Sample result is considered valid. RPD - Relative Percent Difference S-1 - Laboratory container pH was above desired amount. This has no effect on the data. Sample result is considered valid.
TNTC - Too numerous to count U – Undetected W-05 - Highest possible dilutions were made by the laboratory
     
BOD - Biochemical Oxygen Demand BRL - Below Reading Limit COD - Chemical Oxygen Demand
TDS - Total Dissolved Solids TSS - Total Suspended Solids by EPA 160.2 PC - Sample results suspect due to post-calibration results
**This data was only collected in the second permit term. ***This data is only being collected in the third permit term.  


Back to Station Map          Back to Main Monitoring Page          Export Data
 
 CONTACT US | SITE MAP | LEGAL | SYSTEM REQUIREMENTS
 North Central Texas Council of Governments | 616 Six Flags Drive P.O. Box 5888 Arlington, TX 76005-5888
 Main Operator: (817) 640-3300 | Fax: (817) 640-7806