Station Info: PL1402

 
Station ID Year Jurisdiction Watershed Location Description     Latitude         Longitude    
PL1402 2014 Plano Pittman Creek - Spring Creek Spring Creek at 16th Street 33.021317 -96.712406

Sampled Events

1st Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
2/2/2014 9:55:00 AM 2/2/2014 3:55:00 PM Showers associated with a cold front moving across the region in a southeasterly direction initiated during the late morning and faded away during the early afternooon hours. PL1402 0.1 0.05 550
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
2/2/2014 2:00:00 PM 2/2/2014 4:35:00 PM 2/2/2014 2:27:00 PM 2/2/2014 4:30:00 PM 6 1.2 0.8 3.5 31 40.9 The flow end time and date are a result of the sampling equipment being removed at the conclusion of sampling activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
95 27 6 24 2.95 0.07 0.23 <0.06 U <0.002 U 0.011 0.017 J <0.004 U 0.11 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 8.4 16 45500 466

2nd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
4/13/2014 10:10:00 AM 4/13/2014 1:10:00 PM Moderate to heavy thunderstorms moved from the west across the area. PL1402 0.28 0.19 157
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
4/13/2014 10:51:00 AM 4/13/2014 10:55:00 AM 4/13/2014 12:55:00 PM 6 1 3.5 68 68.9 The bubbler module was inoperable at the time of the sampling event. The flow end time and date and average depth could not be determined. Samples were collected manually based upon field observations.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
269 34 6 72 1.61 0.05 0.09 <0.06 U <0.002 U 0.003 J 0.029 <0.004 U 0.029 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
2.3 J 7.5 1395 1300000 730

3rd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
7/17/2014 4:00:00 AM 7/17/2014 7:25:00 AM A large low pressure area moving east across North Texas brought constant rainfall of moderate intensity throughout the day in the Dallas-Fort Worth area. PL1402 0.34 0.27 334
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
7/17/2014 4:25:00 AM 7/17/2014 6:35:00 AM 7/17/2014 4:29:00 AM 7/17/2014 6:32:00 AM 6 1.9 1.3 3.5 75 77.2 The flow end time and date are a result of the sampling equipment being removed at the conclusion of sampling activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
127 163 8.44 41 2.5 J 0.1 0.19 <0.06 U <0.002 U <0.003 U 0.022 <0.004 U 0.034 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 8 5 7500 638

4th Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
10/6/2014 5:10:00 AM 10/6/2014 6:40:00 AM Large storm cells formed northwest of the Dallas Fort-Worth metroplex and moved across the region in a southeast direction bringing light to medium rainfall to the watershed during the early morning. PL1402 0.47 0.47 84
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
10/6/2014 5:40:00 AM 10/6/2014 8:00:00 AM 10/6/2014 5:47:00 AM 10/6/2014 7:50:00 AM 6 1.1 0.8 3.5 67 70.6 None.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
718 75.67 16.7 79 0.91 0.05 0.16 <0.06 U 0.004 J 0.006 J 0.026 0.005 J 0.143 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 8.5 600 82000 235

Station Averages

Station TDS TSS BOD COD Nitrogen Phosphorus
(Dissolved)
Phosphorus
(Total)
Carbaryl Arsenic Chromium Copper Lead Zinc Diazinon Cadmium Oil &
Grease
E.
Coli
Coliform
(Total)
pH
Lab
pH
Field
Specific Conductivity
PL1401 132.8 179.8 7.6 37.9 2.015 0.04 0.175 0.03 0.001 0.005 0.0265 0.002 0.0778 1.05 77 10350 8.2 278.25
PL1402 302.3 74.9 9.3 54 1.993 0.0675 0.168 0.03 0.002 0.005 0.0235 0.003 0.079 1.1 90 77662 7.91 517.25

Key:
< or > - Amount detected is above or below equipment detection limit A - Approximate end time of flow due to power failure A-01 - >400000
B-02 - BOD result calculated from COD analysis D-1 - Elevated reporting limit(s) due to dilution. This has no effect on the data. Sample result is considered valid. DET - Analyte Detected
DRY – Sample results reported on a dry weight basis E - End time of flow due to equipment removal from site IS - Insufficient Sediment within Sample
J - Detected but below the reporting limit N/A - Data not available at this time ND - Analyte not detected at or above the reporting limit
NR - Not Reported NST – No Sample Taken U - Undetected
W-05 - Highest possible dilutions were made by the laboratory Qual – Qualifiers Q-5 - Seed correction outside desired limits. This has no effect on the data. Sample result is considered valid.
Q11 - Insufficient sample for analysis of matrix spike. This has no effect on the data. Sample result is considered valid. RPD - Relative Percent Difference S-1 - Laboratory container pH was above desired amount. This has no effect on the data. Sample result is considered valid.
TNTC - Too numerous to count U – Undetected W-05 - Highest possible dilutions were made by the laboratory
     
BOD - Biochemical Oxygen Demand BRL - Below Reading Limit COD - Chemical Oxygen Demand
TDS - Total Dissolved Solids TSS - Total Suspended Solids by EPA 160.2 PC - Sample results suspect due to post-calibration results
**This data was only collected in the second permit term. ***This data is only being collected in the third permit term.  


Back to Station Map          Back to Main Monitoring Page          Export Data
 
 CONTACT US | SITE MAP | LEGAL | SYSTEM REQUIREMENTS
 North Central Texas Council of Governments | 616 Six Flags Drive P.O. Box 5888 Arlington, TX 76005-5888
 Main Operator: (817) 640-3300 | Fax: (817) 640-7806