nctcog logo
 
environment & development label
 
  Back to Station Map          Back to Main Monitoring Page          Export Data

Station Info: MS1502

 
Station ID Year Jurisdiction Watershed Location Description     Latitude         Longitude    
MS1502 2015 Mesquite North Mesquite Creek North Mesquite Creek at Edward's Church 32.7321111 -96.5505

Sampled Events

1st Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
1/1/2015 1:05:00 AM 1/1/2015 9:15:00 AM Large storms formed southwest of the Dallas Fort-Worth metroplex and moved across the region in a northeast direction bringing light to medium rainfall. MS1502 0.38 0.14 348
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
1/1/2015 6:40:00 AM 1/1/2015 10:10:00 AM 1/1/2015 7:20:00 AM 1/1/2015 9:24:00 AM 6 0.6 0.3 3.5 34 40 The flow end time and date are a result of the sampling equipment being removed at the conclusion of the sampling activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
216 23.78 2.02 <1 U 0.83 0.05 0.08 <0.063 U <0.002 U <0.003 U 0.036 <0.004 U 0.012 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 8.3 20 4000 754

2nd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
4/5/2015 3:55:00 AM 4/5/2015 10:35:00 AM Large storms formed southwest of the Dallas Fort-Worth metroplex and moved across the region in an eastern direction bringing moderate rainfall. MS1502 0.69 0.29 241
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
4/5/2015 5:20:00 AM 4/5/2015 11:20:00 AM 4/5/2015 5:32:00 AM 4/5/2015 7:36:00 AM 6 3.2 1.6 3.5 50 59.9 The flow end time and date are a result of the sampling equipment being removed at the conclusion of the sampling activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
476 15.4 5.89 14 4.8 J 0.09 0.12 <0.06 U <0.002 U <0.003 U 0.011 J <0.004 U 0.02 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 8.2 1100 3200 1021

3rd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
8/19/2015 11:15:00 PM 8/19/2015 2:15:00 AM An isolated storm formed northwest of the Dallas-Fort Worth metroplex and moved across the region in a southeast direction bringing moderate rainfall. MS1502 0.13 0.11 1218
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
8/20/2015 8/20/2015 3:45:00 AM 8/20/2015 1:36:00 AM 8/20/2015 3:40:00 AM 6 1 1 3.5 66 73.6 The flow end time and date are a result of the sampling equipment being removed at the conclusion of the sampling activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
308 1.89 J 2.94 2 J 0.97 0.04 0.05 <0.06 U 0.004 J <0.003 U 0.01 J <0.004 U 0.019 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
11.1 7.9 119 232 1005

4th Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
10/22/2015 9:43:00 PM 10/22/2015 11:43:00 PM Large storms formed southwest of the Dallas Fort-Worth metroplex and moved across the region in a northeast direction bringing heavy rainfall. MS1502 1.04 0.72 887
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
10/22/2015 11:05:00 PM 10/23/2015 2:00:00 AM 10/22/2015 11:17:00 PM 10/23/2015 1:21:00 AM 6 3 2.3 3.5 68 70.4
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
200 330 5.3 17 2.76 0.07 0.07 <0.06 U 0.003 J <0.003 U 0.002 J <0.004 U 0.003 J ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
10 7.96 2500 50000 150

Station Averages

Station TDS TSS BOD COD Nitrogen Phosphorus
(Dissolved)
Phosphorus
(Total)
Carbaryl Arsenic Chromium Copper Lead Zinc Diazinon Cadmium Oil &
Grease
E.
Coli
Coliform
(Total)
pH
Lab
pH
Field
Specific Conductivity
MS1501 414.5 193 3.1 19 8.815 0.0475 0.073 0.0313 0.002 0.002 0.0075 0.002 0.0148 0.93 328 4821 8.18 929.75
MS1502 300 92.8 4 8.4 2.34 0.0625 0.08 0.0304 0.002 0.002 0.0148 0.002 0.0135 5.63 284 3491 8.06 732.5

Key:
< or > - Amount detected is above or below equipment detection limit A - Approximate end time of flow due to power failure A-01 - >400000
B-02 - BOD result calculated from COD analysis D-1 - Elevated reporting limit(s) due to dilution. This has no effect on the data. Sample result is considered valid. DET - Analyte Detected
DRY – Sample results reported on a dry weight basis E - End time of flow due to equipment removal from site IS - Insufficient Sediment within Sample
J - Detected but below the reporting limit N/A - Data not available at this time ND - Analyte not detected at or above the reporting limit
NR - Not Reported NST – No Sample Taken U - Undetected
W-05 - Highest possible dilutions were made by the laboratory Qual – Qualifiers Q-5 - Seed correction outside desired limits. This has no effect on the data. Sample result is considered valid.
Q11 - Insufficient sample for analysis of matrix spike. This has no effect on the data. Sample result is considered valid. RPD - Relative Percent Difference S-1 - Laboratory container pH was above desired amount. This has no effect on the data. Sample result is considered valid.
TNTC - Too numerous to count U – Undetected W-05 - Highest possible dilutions were made by the laboratory
     
BOD - Biochemical Oxygen Demand BRL - Below Reading Limit COD - Chemical Oxygen Demand
TDS - Total Dissolved Solids TSS - Total Suspended Solids by EPA 160.2 PC - Sample results suspect due to post-calibration results
**This data was only collected in the second permit term. ***This data is only being collected in the third permit term.  


Back to Station Map          Back to Main Monitoring Page          Export Data
 
 CONTACT US | SITE MAP | LEGAL | SYSTEM REQUIREMENTS
 North Central Texas Council of Governments | 616 Six Flags Drive P.O. Box 5888 Arlington, TX 76005-5888
 Main Operator: (817) 640-3300 | Fax: (817) 640-7806