nctcog logo
 
environment & development label
 
  Back to Station Map          Back to Main Monitoring Page          Export Data

Station Info: GA0701

 
Station ID Year Jurisdiction Watershed Location Description     Latitude         Longitude    
GA0701 2007 Garland Duck Creek Duck Creek at Shiloh Road 32.9280833 -96.6650555

Sampled Events

1st Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
1/12/2007 5:20:00 PM 1/13/2007 1:45:00 AM A line of showers and thunderstorms associated with a cold frontal system moving across the metroplex traveling from the northwest GA0701 1.49 0.72 204
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
1/12/2007 5:30:00 PM 1/13/2007 5:05:00 AM 1/12/2007 5:39:00 PM 1/12/2007 7:44:00 PM 6 7.5 3.9 3.5 None
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
85 162 <3 U 16.2 1.36 <0.05 U 0.152 *** 0.005 J 0.007 J 0.024 J 0.02 J 0.114 J <0.037 U <0.001 U
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 7.33 7.78 <10 U <10 U ***

2nd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
4/3/2007 7:00:00 PM 4/3/2007 9:45:00 PM A frontal boundary brought rain showers across the metroplex moving from northwest to southeast GA0701 0.12 0.08 88
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
4/3/2007 7:15:00 PM 4/4/2007 4:35:00 AM 4/3/2007 7:35:00 PM 4/3/2007 9:39:00 PM 6 3.2 1.5 3.5 None
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
360 35 23 50 15.6 <0.05 U <0.05 U *** <0.002 U 0.012 J 0.021 J <0.004 U 0.0339 J <0.037 U <0.001 U
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 7.64 7.7 110 9300 ***

3rd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
7/26/2007 6:30:00 PM 7/26/2007 10:10:00 PM Rain associated with afternoon thunderstorms occurred across the Eastern portions of Dallas County GA0701 0.16 0.15 381
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
7/26/2007 6:45:00 PM 7/26/2007 9:00:00 PM 7/26/2007 6:50:00 PM 7/26/2007 8:55:00 PM 6 3.8 3.7 3.5 The bubbler was disconnected as a part of removing the equipment at 2100 on 7/26/07. The peak depth and flow end time and date shown were reported prior to this time.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
364 17.3 5.94 25.6 1 <0.05 U <0.05 U *** 0.05 J <0.003 U 0.0206 J <0.004 U 0.0319 J <0.037 U <0.001 U
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
2.37 J 7.75 6.99 1670 102000 ***

4th Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
10/14/2007 10:50:00 PM 10/15/2007 2:55:00 AM A line of showers and thunderstorms associated with a frontal system moved across the Metroplex traveling in an east southeast direction. GA0701 0.71 0.43 146
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
10/14/2007 10:10:00 PM 10/15/2007 1:35:00 AM 11:00:00 PM 1:03:00 AM 6 1.35 1.02 3.5 71 The flow end time and date are a result of the sampling equipment being removed at the conclusion of the sampling activities.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
304 142 8.32 62 1 <0.05 U 0.24 *** 0.022 J 0.006 J 0.01935 J <0.004 U <0.003 U <0.037 U <0.001 U
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 7.45 8.04 8000 285000 ***

Station Averages

Station TDS TSS BOD COD Nitrogen Phosphorus
(Dissolved)
Phosphorus
(Total)
Carbaryl Arsenic Chromium Copper Lead Zinc Diazinon Cadmium Oil &
Grease
E.
Coli
Coliform
(Total)
pH
Lab
pH
Field
Specific Conductivity
GA0701 278.3 89.1 9.7 38.5 4.74 0.025 0.111 0.02 0.007 0.0212 0.007 0.0453 0.0185 0.0005 1.12 293 6064 7.51 7.43
GA0702 479.5 572.1 11.8 92.2 9.038 0.079 0.15 0.003 0.006 0.0236 0.008 0.0644 0.0185 0.0009 14.83 1798 11344 7.52 7.72
GA0703 328 165.1 7.8 20.8 9.423 0.025 0.48 0.008 0.004 0.0173 0.003 0.0358 0.0185 0.0005 1.83 328 4277 7.39 7.5

Key:
< or > - Amount detected is above or below equipment detection limit A - Approximate end time of flow due to power failure A-01 - >400000
B-02 - BOD result calculated from COD analysis D-1 - Elevated reporting limit(s) due to dilution. This has no effect on the data. Sample result is considered valid. DET - Analyte Detected
DRY – Sample results reported on a dry weight basis E - End time of flow due to equipment removal from site IS - Insufficient Sediment within Sample
J - Detected but below the reporting limit N/A - Data not available at this time ND - Analyte not detected at or above the reporting limit
NR - Not Reported NST – No Sample Taken U - Undetected
W-05 - Highest possible dilutions were made by the laboratory Qual – Qualifiers Q-5 - Seed correction outside desired limits. This has no effect on the data. Sample result is considered valid.
Q11 - Insufficient sample for analysis of matrix spike. This has no effect on the data. Sample result is considered valid. RPD - Relative Percent Difference S-1 - Laboratory container pH was above desired amount. This has no effect on the data. Sample result is considered valid.
TNTC - Too numerous to count U – Undetected W-05 - Highest possible dilutions were made by the laboratory
     
BOD - Biochemical Oxygen Demand BRL - Below Reading Limit COD - Chemical Oxygen Demand
TDS - Total Dissolved Solids TSS - Total Suspended Solids by EPA 160.2 PC - Sample results suspect due to post-calibration results
**This data was only collected in the second permit term. ***This data is only being collected in the third permit term.  


Back to Station Map          Back to Main Monitoring Page          Export Data
 
 CONTACT US | SITE MAP | LEGAL | SYSTEM REQUIREMENTS
 North Central Texas Council of Governments | 616 Six Flags Drive P.O. Box 5888 Arlington, TX 76005-5888