Station Info: DL0901

 
Station ID Year Jurisdiction Watershed Location Description     Latitude         Longitude    
DL0901 2009 Dallas Southeast Dallas Northeast corner of Easter Avenue and E. Kiest Boulevard 32.7128444 -96.7961472

Sampled Events

1st Quarter:
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
3/11/2009
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
202 15 4.22 40.1 1.34 0.243 0.258 *** <0.003 0.004 0.01 0.017 0.054 <0.05 <0.003
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
4.94 7.53 3448 173290 ***

2nd Quarter:
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
4/27/2009
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
320 26 3.11 16.1 3 0.138 0.224 *** 0.004 <0.003 0.005 <0.003 0.041 <0.05 <0.003
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
<1.1 7.4 96106 101120 ***

2nd Quarter:
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
6/11/2009 Additional second quarter sample collected
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
156 52 7.07 19.7 NA 0.699 1.35 *** 0.006 0.003 0.007 0.007 0.033 <0.05 <0.003
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
<1.1 7.5 7215 241960 ***

3rd Quarter:
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
8/21/2009
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
32 85 17.3 75.5 1.72 0.088 0.257 *** <0.003 0.002 0.01 0.005 0.024 <0.375 <0.001
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
1.71 7.97 24196 241960 ***

4th Quarter:
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
11/16/2009
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon
(µg/L)
Cadmium
Total (mg/L)
216 270 75.1 301 4.91 0.407 0.602 *** 0.005 0.004 0.0206 0.008 0.076 <0.375 <0.006
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
<1.1 7.03 38700 241960 ***

Station Averages

Station TDS TSS BOD COD Nitrogen Phosphorus
(Dissolved)
Phosphorus
(Total)
Carbaryl Arsenic Chromium Copper Lead Zinc Diazinon Cadmium Oil &
Grease
E.
Coli
Coliform
(Total)
pH
Lab
pH
Field
Specific Conductivity
DL0901 185.2 89.6 21.4 90.5 2.743 0.315 0.538 0.004 0.003 0.0105 0.008 0.0456 0.09 0.0016 1.66 18621 190094 7.39
DL0902 127.6 256.6 30 103.5 12.35 0.232 0.449 0.002 0.014 0.0207 0.028 0.1015 0.09 0.0016 1.97 34218 241960 7.61
DL0903 124.4 386.8 23.8 87.4 2.783 0.1592 0.454 0.002 0.009 0.015 0.016 0.0734 0.09 0.0016 0.88 6978 153976 7.52

Key:
< or > - Amount detected is above or below equipment detection limit A - Approximate end time of flow due to power failure A-01 - >400000
B-02 - BOD result calculated from COD analysis D-1 - Elevated reporting limit(s) due to dilution. This has no effect on the data. Sample result is considered valid. DET - Analyte Detected
DRY – Sample results reported on a dry weight basis E - End time of flow due to equipment removal from site IS - Insufficient Sediment within Sample
J - Detected but below the reporting limit N/A - Data not available at this time ND - Analyte not detected at or above the reporting limit
NR - Not Reported NST – No Sample Taken U - Undetected
W-05 - Highest possible dilutions were made by the laboratory Qual – Qualifiers Q-5 - Seed correction outside desired limits. This has no effect on the data. Sample result is considered valid.
Q11 - Insufficient sample for analysis of matrix spike. This has no effect on the data. Sample result is considered valid. RPD - Relative Percent Difference S-1 - Laboratory container pH was above desired amount. This has no effect on the data. Sample result is considered valid.
TNTC - Too numerous to count U – Undetected W-05 - Highest possible dilutions were made by the laboratory
     
BOD - Biochemical Oxygen Demand BRL - Below Reading Limit COD - Chemical Oxygen Demand
TDS - Total Dissolved Solids TSS - Total Suspended Solids by EPA 160.2 PC - Sample results suspect due to post-calibration results
**This data was only collected in the second permit term. ***This data is only being collected in the third permit term.  