Station Info: AR1403

 
Station ID Year Jurisdiction Watershed Location Description     Latitude         Longitude    
AR1403 2014 Arlington Rush Creek - Village Creek Rush Creek at Woodland Park Blvd 32.713889 -97.172778

Sampled Events

1st Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
2/2/2014 9:53:00 AM 2/2/2014 3:53:00 PM Light sleet/rain mix moving west to east. AR1403 0.17 0.09 1029
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
2/2/2014 2:43:00 PM 2/2/2014 11:59:00 PM 2/2/2014 2:43:00 PM 2/2/2014 4:51:00 PM 6 3.5 29 44.3 Samples were collected and taken to the lab. While the sampler was disconnected from power the internal battery failed. This resulted in level data being lost.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
483 16 8 28 1.77 0.03 0.25 <0.06 U 0.002 J 0.005 J 0.02 <0.004 U 0.084 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 8.4 24 49500 753

2nd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
4/6/2014 4:20:00 AM 4/6/2014 1:10:00 AM Heavy rain moving southwest to northeast. AR1403 0.25 0.09 514.5
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
4/6/2014 7:45:00 AM 4/6/2014 11:55:00 AM 4/6/2014 7:48:00 AM 4/6/2014 9:56:00 AM 6 0.686 0.303 3.5 47 57
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
457 38 12 36 2.27 0.09 0.13 <0.06 U <0.002 U <0.003 U 0.013 J <0.004 U 0.059 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
2.8 J 8.1 410 18700 998

3rd Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
7/14/2014 5:20:00 PM 7/14/2014 8:25:00 PM Very heavy thunderstorms moved slowly from west to east. AR1403 1.16 1.06 480
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
7/14/2014 5:30:00 PM 7/14/2014 6:01:00 PM 7/14/2014 8:01:00 PM 6 3.5 77 81.2 While retrieving data a connection error occurred. As a result, storm data for 3rd quarter was not retrieved from AR1403. The flow end time, date, and average depth could not be determined.
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
1940 514 23.3 88 3.68 0.11 0.2 <0.06 U <0.002 U 0.003 J 0.018 J <0.004 U 0.048 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
1.8 J 8.1 <1 U 5200 339

4th Quarter:
Storm
Summary
Storm
Start
Storm
End
Description Rainfall
Station
Rainfall
Total (in)
Peak
Rate (in)
Antecedent Dry
Period (hrs)
10/2/2014 3:55:00 PM 10/2/2014 4:50:00 PM Heavy thunderstorms moved quickly from west to east. AR1403 1.24 1.24 616
Collection
Info
Flow
Start
Flow
End
1st Aliquot
Collected
Last Aliquot
Collected
# Aliquots
Collected
Peak
Depth (ft)
Avg
Depth (ft)
Sample
Volume (gal)
Ambient Air
Temp (°F)
Water
Temp (°F)
Sample
Comments
10/2/2014 4:05:00 PM 10/3/2014 3:00:00 PM 10/2/2014 4:10:00 PM 10/2/2014 6:18:00 PM 6 6.867 2.246 3.5 78 72.4
Composite TDS
(mg/L)
TSS
(mg/L)
BOD
(mg/L)
COD
(mg/L)
Nitrogen
Total (mg/L)
Phosphorus
Dissolved (mg/L)
Phosphorus
Total (mg/L)
Carbaryl
Total (mg/L)
Arsenic
Total (mg/L)
Chromium
Total (mg/L)
Copper
Total (mg/L)
Lead
Total (mg/L)
Zinc
Total (mg/L)
Diazinon Cadmium
138 48 11.4 40 0.34 J 0.09 0.41 <0.06 U 0.003 J 0.006 J 0.021 0.005 J 0.104 ** **
Grab Oil & Grease
(mg/L)
pH Lab
(su)
pH Field
(su)
E.Coli
(col/100mL)
Total Coliform
(col/100mL)
Specific Conductivity
(uS/cm)
  PDF icon  Download Lab Report
<1.4 U 8.4 700 30000 177

Station Averages

Station TDS TSS BOD COD Nitrogen Phosphorus
(Dissolved)
Phosphorus
(Total)
Carbaryl Arsenic Chromium Copper Lead Zinc Diazinon Cadmium Oil &
Grease
E.
Coli
Coliform
(Total)
pH
Lab
pH
Field
Specific Conductivity
AR1401 621.3 251.6 8.1 30 6.954 0.1106 0.185 0.03 0.001 0.005 0.0195 0.003 0.0353 1.4 81 6259 8.51 513.5
AR1402 620 119.3 9.7 45.8 1.503 0.14 0.228 0.03 0.002 0.006 0.018 0.003 0.0455 2.3 93 12754 8.36 825
AR1403 754.5 154 13.7 48 2.015 0.08 0.248 0.03 0.002 0.004 0.018 0.003 0.0738 1.5 43 19494 8.22 566.75

Key:
< or > - Amount detected is above or below equipment detection limit A - Approximate end time of flow due to power failure A-01 - >400000
B-02 - BOD result calculated from COD analysis D-1 - Elevated reporting limit(s) due to dilution. This has no effect on the data. Sample result is considered valid. DET - Analyte Detected
DRY – Sample results reported on a dry weight basis E - End time of flow due to equipment removal from site IS - Insufficient Sediment within Sample
J - Detected but below the reporting limit N/A - Data not available at this time ND - Analyte not detected at or above the reporting limit
NR - Not Reported NST – No Sample Taken U - Undetected
W-05 - Highest possible dilutions were made by the laboratory Qual – Qualifiers Q-5 - Seed correction outside desired limits. This has no effect on the data. Sample result is considered valid.
Q11 - Insufficient sample for analysis of matrix spike. This has no effect on the data. Sample result is considered valid. RPD - Relative Percent Difference S-1 - Laboratory container pH was above desired amount. This has no effect on the data. Sample result is considered valid.
TNTC - Too numerous to count U – Undetected W-05 - Highest possible dilutions were made by the laboratory
     
BOD - Biochemical Oxygen Demand BRL - Below Reading Limit COD - Chemical Oxygen Demand
TDS - Total Dissolved Solids TSS - Total Suspended Solids by EPA 160.2 PC - Sample results suspect due to post-calibration results
**This data was only collected in the second permit term. ***This data is only being collected in the third permit term.  


Back to Station Map          Back to Main Monitoring Page          Export Data
 
 CONTACT US | SITE MAP | LEGAL | SYSTEM REQUIREMENTS
 North Central Texas Council of Governments | 616 Six Flags Drive P.O. Box 5888 Arlington, TX 76005-5888